Corning Cable FREEDM Loose Tube Gel-Free Single-Mode Plenum Cable

(Model # 048EWP-T4101DA3)
Corning FREEDM Loose Tube Gel-Free Single-Mode Plenum Cable
Corning
Image Shown is 24-Fiber Count

Note: Picture may not represent the actual product. We are continuously working on improving our website and reserve the right to change specifications, availability, and pricing without prior notice.

  • $18,774.45

  • Availability:
  • Usually ships in 3 weeks
  • Fiber Count
  • Minimum Length
  • Metal Costs Rapidly Changing
  • Cable pricing is subject to change. You will be contacted if necessary.
  • Shipping Costs
  • Additional shipping charges may apply based on shipping insurance.
Qty:
FREEDM Loose Tube Gel-Free Plenum Cable are flame-retardant, indoor/outdoor, plenum-rated cables suitable for installation in inter- and intrabuilding backbones in aerial, duct and riser or plenum applications.
Plenum Cable Features:
  • Loose Tube design offers mechanical ruggedness and environmental durability while the all-dielectric cable construction requires no grounding or bonding
  • Water-swellable yarn eliminates the need for gel-filling compound and allows more efficient and craft-friendly cable preparation
  • The flexible, flame retardant outer jacket is UV resistant and enables direct exposure to sunlight
  • Cable has Interlocking Armor for special applications requiring additional mechanical durability
  • The plenum rating of this cable eliminates the need to transition splice when entering the building and minimizes routing restrictions once inside the building
  • Color-coded 250 µm Fibers (12 Fibers per Tube)
  • Single-Mode Fiber Code, ITU 652.D Compliant
  • Wavelength: 1310/1383/1550 nm
  • Maximum Attenuation: 0.4/0.4/0.3 dB/km
  • Plenum Outer Jacket
  • Cable Marking Lengths are in Feet
  • Nominal Cable Weight: 86 lb/1000 ft
  • Nominal Outside Diameter: 0.44"
  • Maximum Tensile Load, Short-Term: 600 lbf
  • Maximum Tensile Load, Long-Term: 180 lbf
  • Minimum Bend Radius, Loaded: 6.6"
  • Minimum Bend Radius, Installed: 4.4"
  • Meeting the requirements of the National Electric Code (NEC) Article 770 - The cables are also OFNP and FT-6 listed and Meet Burn Test Criteria
  • Design and Test Criteria: ANSI/ICEA S-104-696; NFPA 262 (for Plenum, Riser and General Building Applications)
  • Available Fiber Counts: 24, 36, 48, and 60
Minimum Order Quantity is 2624 Feet. Larger amounts of Cable may be ordered. Please contact our Sales Department if needed.
SKU Fiber Count Minimum Length
024EWP-T4101DA3 24 2624 Feet
036EWP-T4101DA3 36 2624 Feet
048EWP-T4101DA3 48 2624 Feet
060EWP-T4101DA3 60 2624 Feet
NOTE: Viewing PDF documents requires the free Adobe® Reader® version 5.0 or greater.If you don't already have it installed, you will need to download and install it before using PDF documents.
Get Adobe Reader