Schneider Electric Symmetra LX 16kVA Scalable to 16kVA N+1 Tower, 208/240V

(Model # SYA16K16P)
Schneider Electric Symmetra LX 16kVA Scalable to 16kVA N+1 Tower, 208/240V
Schneider Electric

Note: Picture may not represent the actual product. We are continuously working on improving our website and reserve the right to change specifications, availability, and pricing without prior notice.

  • $14,170.62

  • Availability:
  • Usually ships in 10 days
  • Dimensional Weight
  • Shipping Weight is calculated using actual physical product dimensions.
  • Multiple Quantities
  • Please call for freight costs on multiple quantities.
  • Shipping Costs
  • Additional shipping charges may apply. You will be contacted if necessary.
Qty:
Engineered to deliver the highest level of business continuity possible the Symmetra LX uses a modular redundant architecture that can scale power and run-time as demand increases or when higher levels of availability are required. APC Symmetra, 12.8 kW / 16 kVA, Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model.
SYA16K16P Symmetra Tower Features:
  • LCD display
  • Network manageable
  • Hot-swappable batteries
  • Smart Slot
  • Extended Run Time
  • Shippable with modules installed: Enables pre-installation UPS staging and testing and faster installation
  • Removable input/output wiring tray: Allows quick and easy installation and maintenance of the UPS
  • Modular design: Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules
  • Configurable for N+1 internal redundancy: Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load
  • Redundant Intelligence Modules: Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions
  • Hot-swappable intelligence modules: Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement
  • Hot-swappable power modules: Ensures clean, uninterrupted power to protected equipment during Power Module replacement
  • Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Power Modules connected in parallel: Enhances availability by allowing immediate, seamless recovery from isolated module failures
  • Battery modules connected in parallel: Delivers higher availability through redundant batteries
  • Automatic internal bypass: Supplies utility power to the connected loads in the event of a UPS overload condition or fault
  • Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power
  • Scalable power capacity: Reduces UPS over-sizing costs today by allowing quick upgrades later
  • Scalable runtime: Allows additional run time to be quickly added as needed
  • Plug-and-Play external batteries: Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS
  • Field-replaceable power distribution panel: Ensures compatibility with equipment that has different plug types.
  • Programmable frequency: Ensures compatibility with different input frequencies
  • Manageable external batteries: Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime
  • Network manageable: Provides remote management of the UPS over the network
  • InfraStruXure Manager Compatible: Enables centralized management via the APC InfraStruXure Manager
  • LCD display: Alpha-Numeric Display which displays system parameters and alarms
  • Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging
  • SmartSlot: Customize UPS capabilities with management cards
  • Output Power Capacity: 12.8 kW / 16 kVA
  • Max Configurable Power: 12.8 kW / 16 kVA
  • Nominal Output Voltage: 120V, 208V
  • Output Voltage Note: Configurable for 120/208 or 120/240 output voltage
  • Output Voltage Distortion: Less than 5% at full load
  • Output Frequency (sync to mains): 47 - 63 Hz
  • Other Output Voltages: 240
  • Crest Factor: up to 5 : 1
  • Topology: Double Conversion Online
  • Waveform Type: Sine wave
  • Output Connections: (1) Hard Wire 4-wire (2PH + N +G)
  • Bypass: Internal Bypass (Automatic and Manual)
  • Nominal Input Voltage: 208V
  • Input Frequency: 45 - 65 Hz (auto sensing)
  • Input Connections: Hard Wire 4-wire (2PH+N+G)
  • Input voltage range for main operations: 96 - 138 (Line to Neutral)V
  • Other Input Voltages: 240V
  • Input Total Harmonic Distortion: Less than 7% for full load
  • Battery Type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
  • Included Battery Modules: 4
  • Typical recharge time: 3 hour(s)
  • Replacement Battery: SYBT5
  • Dimensions: 36.90" H x 19.00" W x 28.60" D