Tripp Lite SmartOnline 3000VA 3U Rack/Tower On-Line Double-Conversion UPS with 110/120V NEMA Outlets and XR Runtime

(Model # SU3000RTXR3U)
Tripp Lite SmartOnline 3000VA 3U Rack/Tower On-Line Double-Conversion UPS with 110/120V NEMA Outlets and XR Runtime
Tripp Lite

Note: Picture may not represent the actual product. We are continuously working on improving our website and reserve the right to change specifications, availability, and pricing without prior notice.

  • $2,058.12

  • Availability:
  • Usually ships in 1 week
  • Dimensional Weight
  • Shipping Weight is calculated using actual physical product dimensions.
  • Manufacturer
  • 2 Year Limited Warranty
  • Multiple Quantities
  • Please call for freight costs on multiple quantities.
  • Shipping Costs
  • Additional shipping charges may apply. You will be contacted if necessary.
  • Shipping Insurance
  • Additional shipping charges may apply based on shipping insurance and weight.
Qty:
SmartOnline 3000VA 3U Rack/Tower On-Line Double-Conversion UPS with 110/120V NEMA Outlets and XR Runtime is ideal for critical voice, data, medical and industrial network applications.
UPS Features:
  • True online, double-conversion UPS provides regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions
  • Special "XR" version offers larger internal batteries for longer runtimes than standard "XL" model
  • Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
  • Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
  • Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values
  • Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs
  • Standard internal battery set offers 30 minutes runtime at half load (1200W) and 12 minutes at full load (2400W)
  • Compact rackmount form factor installs using only 3 rack spaces (3U) with a maximum installed depth of 26"
  • Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
  • Network interfaces support simultaneous communications via built-in USB, DB9 serial/contact-closure and SNMPWEBCARD slot
  • HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
  • Built-in emergency power off (EPO) interface with cable
  • Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has four outlets)
  • Front panel LEDs offer current monitoring and battery charge level information
  • Output Volt Amp Capacity: 3000VA
  • Output Watt Capacity: 2400 watts
  • Frequency Compatibility: 60 Hz
  • Built-in UPS Output Receptacles: Four 5-15R outlet, four 5-15/20R outlets, and one L5-30R outlet(s)
  • Full Load Runtime: 12 minutes (2400w)
  • Half Load Runtime: 30 minutes (1200w)
NOTE: Viewing PDF documents requires the free Adobe® Reader® version 5.0 or greater.If you don't already have it installed, you will need to download and install it before using PDF documents.
Get Adobe Reader