The full modular entrance station is made of specially designed, vandal resistant zinc diecast panels, and is weather-resistant while weathering hoods and surface mount boxes are available upon request. The system's apartment stations (GF-1MD audio/video & GF-1D audio only) are compact and slim, designed for surface mount installation and are equipped with door release button and 2 additional service buttons. The GF is flexible, allowing users to mix and match modules to create the exact system configuration and features for their own needs. And with the GF video expansion module, you can connect up to 250 audio/video monitors to the system (the current system is limited to 150 stations). Due to the advanced features and easy installation, the GF system is the ideal communication solution for new and existing multi-apartment applications.
Features:
- One to five entrance panels and 250 tenant locations (Note wire distance specifications on larger systems)
- Both audio/video and audio-only entrance panels can be combined in the same system
- Flush mount modular design allows the entrance panel to have digital keypad calling and LCD display, or individual call buttons for each tenant
- Digital entrance panel kits available for easy designing, selling, and installation
- Up to two inside audio/video or audio-only stations for easy communication with visitor
- Security Guard or Concierge Station can be included to provide communication from office/lobby to tenants.
- Panic call switch can be added to tenant locations for emergency calling to guard/concierge
- Simple wiring with only two sets of 2 conductor cable run in common throughout the system (One pair for audio and one pair for video)
- Access control from inside station to calling entrance station (door release)
- Optional individual doorbell at each tenant's door to ring inside station (different tone)
- Door release timer (5~20 seconds), allowing easy entry of postal or delivery workers
Specifications | |
---|---|
Power Source | 24V DC, 0.7A Max. (30mA in standby) Use PS-2410LC only. |
Power Supply | PS-2410LC for each type of adaptor. (One each for GF-BC, GF-VBC/A, GFW-VBC. On additional GF-VBC/A if two monitors are included per tenant.) |
Current Consumption | GF-BC: 0.7A, 30mA in standby
GF-VBC/A: 0.95A, 20mA in standby GF-NS: 80mA (continuous) |
Station Capacity | Maximum 250 total tenant addresses with 10- key digital calling. Max 100 stations when using individual tenant call buttons. |
Entrance Stations | Max. 5 (audio/video or audio-only) |
Apartment Station | Max. 2 stations per apartment, intermixable (or less for larger systems. Max.150 GF-1MD's per system) |
Max. stations per trunk line | 50 GF-1D's
25 GF-1MD's (Either loop wired or using GF-4Z's) |
Trunk Lines | 6 Video trunks from GF-VBC/A
Any number of audio trunks from junction point |
Talk Path | Single channel with privacy |
Calling Tones | Electronic ring tone from entrance station(s)
Differentiated ring tone from individual doorbell Door Release Contact 4A at 24V AC/DC (EL, EL terminals on GF-DA/A or GF-DA/B, dry closure) |
Wiring | 2-wire common bus wiring from Entrances to GF-BC
2-wire common bus wiring from Entrances to GF-VBC/A 2-wire common bus wiring from GF-VBC/A to GF-1MD's 2-wire common bus wiring from GF-BC to GF-1MD's or GF-1D's |
Wire | Use Aiphone wire #872002 for Audio Pair. 2 conductors, solid copper, shielded, polyethylene insulation, 20 AWG.
Use Aiphone wire #871802 for Audio Pair. 2 conductors, solid copper, PE insulation, FPLR, 18 AWG. NOTE: Proper operation or warranty for the system is not guaranteed with wire other than specified. |
Distance | GF-BC to Junction Point: 16' with 20AWG
GF-VBC/A to Entrance Stn: 330' with 18AWG GF-BC & GF-VBC/A to PS-2410LC: 16' with 20AWG GF-VBC/A to farthest GF-1MD: 500' with 18AWG (w/1 monitor); 330' with 18AWG (w/2 monitors) GF-BC to farthest Audio Only Entrance(s): 980' with 20AWG GF-BC to farthest Handset station: 980' with 20AWG Total cumulative audio wire distance must not exceed 7,920' per system with 20AWG |
Entrance Panel Kits:
MODEL
DESCRIPTION GFV-DES 10- Key Audio/Video Entrance Panel GFA-DES 10- Key Audio-Only Entrance Panel
Entrance Panel Modular Components:
MODEL | DESCRIPTION | MODEL | DESCRIPTION |
---|---|---|---|
GF-VA | Video Module | GF-AD | Address Module |
GF-VP | Video Module Panel | GF-AP | Address Panel |
GF-NS/A | Digital LCD Display Module | GF-2F | 2-module front frame |
GF-NSP | LCD Display Module Panel | GF-3F | 3-module front frame |
GF-10K | 10- Key Module | GF-2B | 2-module back box |
GF-10KP | 10-Key Module Panel | GF-3B | 3-module back box |
GF-DA/B | Audio Module | GF-102H | 2 Module Rain Hood (1H x 2V) |
GF-DP | Audio Module Panel | GF-102HB | 2 Module Surface Mount Rain Hood (1H x 2V) |
GF-SW | Call Switch Module | GF-103H | 3 Module Mount Rain Hood (1H x 3V) |
GF-1P | 1- Call button Panel | GF-103HB | 3 Module Surface Mount Rain Hood (1H x 3V) |
GF-2P | 2-Call button Panel | GF-202H | 4 Module Mount Rain Hood (2H x 2V) |
GF-3P | 3-Call button Panel | GF-202HB | 4 Module Surface Mount Rain Hood (2H x 2V) |
GF-4P | 4-Call button Panel | GF-203H | 6 Module Mount Rain Hood (2H x 3V) |
GF-BP | Blank Panel | GF-203HB | 6 Module Surface Mount Rain Hood (2H x 3V) |
See product brochure or instructions, or contact Technical Support for assistance.
Additional Equipment Required:
MODEL | DESCRIPTION |
---|---|
GF-1MD | Inside monitor/handset station with door release for systems without a concierge station or panic call feature
(1 or 2 per apartment, max 250 monitors per system) |
GF-1D | Audio handset with door release for systems without a concierge station or panic call feature
(1 or 2 per apartment, max 250 total stations per system, audio and video combined) |
GF-1MDK | Inside monitor/handset station with door release for systems with a concierge station or panic call feature
(1 or 2 per apartment, max 250 monitors per system) |
GF-1DK | Audio handset with door release for systems with a concierge station or panic call feature
(1 or 2 per apartment, max 250 total stations per system, audio and video combined) |
GF-BC | Audio Bus Control Unit (1 per system) |
GF-VBC/A | Video Bus Control Unit for systems with a concierge station(1 per system) |
GFW-VBC | Long distance/high capacity video control unit (Max. 2 per system) |
GF-MK Concierge Station | Max two per system. Requires use of:
GF-1DK or GF-1MDK Tennant stations GF-DS/B Audio module GF-VBC/A Video Bus control unit |
GF-4Z | 4-Monitor Video Distribution Adaptor (1 per 4 monitors) |
PS-2410LC | Power supply (1 per GF-BC, 1 per GF-VBC(or GF-VBC/A),
1 if GF-NS's are included in system ) |
Additional Optional Equipment:
MODEL | DESCRIPTION |
---|---|
GFW-S | Desk stand for GF-MK |
MCW-S | Desk stand for GF-1MD |
W-DIN11 | Din Rail Mounting Bracket (1 per GF-BC, GF-VBC, GF-VBC/A, GF-4Z) |
GF-C | Connecting Wire (optional, for large entrance direct-selection panels with audio module installed in center of panel.) |
GFK-PS | Panic Call Switch |
MAW-B | External Light Relay |